Purpose of Operating Instructions
The aim of the present operating instructions is to ensure the correct and safe operation of the Jungheinrich SLH 200 charger. The SLH 200 will hereafter be referred to as the charger. The operating instructions must always be available and stored in the vicinity of the charger. The operating instructions must be read and applied by anyone involved in operating the charger, including shipping, assembly and installation, operation, maintenance and disassembly work.
For commercial use, the relevant work safety guidelines, standards and regulations of the place or country of operation must be observed alongside the present operating instructions.
For further information beyond the scope of the operating instructions, please consult with the manufacturer's specialist technicians. All documentation is copyright protected. The transfer or reproduction of documentation, including excerpts, as well as the assessment and dissemination of its content are prohibited unless expressly permitted.
The operating instructions are a major component of the charger. The owner shall ensure that the operating instructions are permanently in the vicinity of the charger, and that operating personnel shall be notified of these guidelines. The owner shall add further instructions regarding national accident prevention and environmental protection regulations to the operating instructions, including information on supervisory and reporting obligations, taking into account particular company practices e.g. in terms of work organization, work processes and the personnel employed.
Apart from the operating instructions and the current accident prevention regulations in force in the country and place of use, generally recognised technical regulations for safe and proper use shall be observed.
Jungheinrich SLH 200 Assembly and Installation Safety Instructions
Before installing the charger, check that all the components have been supplied against the delivery notes. If anything is missing, immediately contact the manufacturer. The place of operation must be weather-proof and dry. The ambient temperature at the site must not fall below 0°C or exceed 40°C. Avoid the build-up of heat within the charger, e.g. through heat sources or by blocking the air vents.
The location site must be sufficiently ventilated to distribute (reduce) charging gases which may arise (acid fog, electrolytic gas) and prevent the build-up of explosive gas mixtures. The site must not contain excessive dust. Avoid the occurrence of conductive dust (soot, metal).
No liquid must enter the inside of the charger. The distance between the charger and inflammable materials must be at least 2.5m horizontally. It is forbidden to store inflammable materials, e.g. in shelves, or to use inflammable materials above the charger. There must be at least a 5.00m gap between fire and explosive-hazardous areas. The charger must be protected against overload or stress. In particular, no components must be damaged during transport and when being handled. Avoid contact with electronic components.
Jungheinrich SLH 200 Troubleshooting and Repairs Safety Instructions
Contact the manufacturer prior to opening the housing for maintenance and repair purposes. Prior to carrying out maintenance or repair work, always disconnect the charger from the mains. After switching off the charger, wait for at least five minutes before opening the panels and housing.
No changes or modifications may be made to the charger which could affect safety without obtaining the manufacturer’s approval. This also applies to the assembly and setting of safety mechanisms. In particular make sure that no safety, leakage or air distances are reduced. Spare parts used must meet the technical requirements specified by the manufacturer. This requirement is always met by original manufacturer’s spare parts.
Jungheinrich SLH 200 Product Functional Description
The SLH 200 charger is designed to charge lead acid accumulators. Depending on the preset charging program, wet cell batteries or sealed, maintenance-free traction batteries can be charged. The charger has an adjustable, high-frequency power part, a micro-processor controlled charging electronics system and a control/display panel with buttons and a charge status light, as well as a graphic enhanced LCD display. The charging program for the respective battery type is factory-set to the customer’s requirements.